Customization: | Available |
---|---|
Certification: | ISO9001, CE |
Salt Rejection Rate: | 99.0% |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Flow chart of seawater desalination RO Filter system
Working process
1. Raw water pump-- provide the pressure to quartz sand filter/active carbon filter.
2. Multi-medium filter--get rid of turbidity, suspended matter, organic matter, colloid, etc.
3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, etc..
4. High pressure pump--Provide the high pressure to RO membrane ro.
5.RO system-- main part of the plant. The RO membrane's desalting rate can reach 98%, removing over 98% ions.
NOS. | Items | Information |
1. Pre-treatment |
Sea water tank | Store sea water, let it have a sedimentation before entering the plant. (Owner supplied) |
Feed water pump | Provide power for pretreatment part. CNP pumps ,Grundfos pumps or other brands | |
Dosing system | Add the flocculant. | |
Quartz sand filter | Quartz sand, used to remove iron,colloid,silt etc, to make effluent water cleaning. | |
Active carbon filter | Remove color, free chloride, organic matter, harmful matter, etc. | |
Dosing system | Detail dosing system will be decided by: source quality & treated water quality requirements. Normal including: inhibitor dosing, PH dosing, reducing dosing, germicide dosing. |
|
2. RO sea water plug system | Security filter | Prevent large particles, iron, dust, SS matter, impurity into the RO membrane. |
HP pump | Provide power for RO. CNP pumps ,Grundfos pumps,or other brands. | |
RO membrane | Removes: lead, cooper, barium, chromium, mercury, sodium, cadmium, fluoride, nitrite, nitrate, and selenium. |
|
3. Control system | Control panel | Auto type. |
Touch screen | Convenience for user to operate. | |
Electricity components | Schneider/Omron/Siemens | |
Plant skid | Ss304 or CS |
Qingdao EVU Environmental & Engineering Equipment Co.,Ltd(EVU) has key technological inputs from it's German partners and over more than 20 years water treatment experience.
Engaged in engineering consulting, design, general contracting and equipment manufacturing of water treatment equipment. Its business spectrum covers both domestic and industrial waste water treatment, pure water treatment, seawater desalination and water recycling.
EVU has very strong commitment to the four cardinal principles of quality standards, system stability, cost control and service-oriented principles as the basis for its survival and development.
1.System can produce water continuously and high degree automation.
2.No need chemical to regenerate, easy operation and maintenance.
3.Core components of ro system are imported USA DOW membranes.
4.Automatic switch on when low water level, and switch off when high water level
5.System flushes RO membranes automatically, reducing membranes polluted speed.
6.Water shortage protection for multi-stage pump
7.Product water conductivity meter can monitor water quality online continuously.
8.Low operation cost and long life span
1.Provide equipment certification and installation operating instructions.
2.Provide one-year spare parts.
3.Provide technical advisory services.
4.Provide guidance staff for installation and commissioning.
Q: What is Reverse Osmosis?
A: Reverse osmosis (R/O) is a water treatment process in which water is forced through a semi-permeable membrane that has very small holes or "pores". Clean water passes through and impurities that are too big to pass through the membrane are left behind and flushed away.
Q: How Does Reverse Osmosis Work?
A: Reverse osmosis systems purify water by forcing pressurized water through a very fine, plastic membrane. If the raw water being treated comes from a well or another private source, disinfection and pre-filters (to remove chlorine and/or particulates/sediment) may be needed in advance of the R/O unit to remove contaminants that can foul or damage the membrane.
Q: How Do I Know What Size Unit to Buy?
A: R/O units are rated according to the amount of treated water produced per day. For example, one type of unit produces 5000 liters of treated water per day under its design conditions. In reality, conditions frequently vary. Line pressure is often lower, water will frequently be colder than 25° C and backpressure in the storage tank will likely reduce the performance of the unit. Consequently, you should examine water conditions and buy a larger rated unit than needed if any of the above problems are noted
Q: Material of reverse osmosis system?
A: You can choose FRP filter + U-PVC pipe, stainless steel filter + U-PVC pipe or total stainless steel.
Q: What is packing of this machine? Is it suitable for shipment?
A: Machine will be packed by standard wooden case. It is suitable for shipment. After you receive machine, you only need to open wooden case to pick up machine.
Q: Is this machine easy to install? Will you arrange engineer to help me install?
A: This machine is very easy for install. The machine you received is assembled. You will only need to put material inside to filters, and then backwash, fast rinse filters. It is very easy for you to follow our English instruction and video.
Q: How can I pay you?
A: After we confirmed order, I will send you contract sales with our company bank information. You can transfer money to our company bank account by T/T.
Q: If there is problems of machine, how can I solve?
A: You can contact us by e-mail or skype, and then tell us problems, send pictures. If it is in one year warranty time, we will send you spare parts for free. If it is more than 1 year, we will help you to find problems, and you can buy spare parts from us or in locally.