| Customization: | Available |
|---|---|
| Certification: | ISO9001, CE, SGS |
| Salt Rejection Rate: | 98.0% |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Model | SWRO- | |
| Quantity | 1 | set |
| Product Water Flow | 0.5-20 | m3/h |
| TDS of Raw Water(≤) | 35000 | mg/L |
| TDS of Product Water(≤) | 1000 | mg/L |
| Recovery Rate(≥) | 20 | % |
| Desalination Rate(≥) | 98.00 | % |
| Rated Power | KW | |
| Operating Power | KW | |
| Operating Temperature | 25~35 | ºC |
| Operating PH | 6~9 | |
| Free Chlorine of Raw Water (≤) | 0.1 | mg/L |
| Operating Pressure (≤) | 6 | Mpa |
| Voltage | 380 | V |
| Frequency | 50 | HZ |
| Phase | 3 | ph |
| Size | m |
| NOS. | Items | Information |
| 1. Pre-treatment |
Sea water tank | Store sea water, let it have a sedimentation before entering the plant. (Owner supplied) |
| Feed water pump | Provide power for pretreatment part. CNP pumps ,Grundfos pumps or other brands | |
| Dosing system | Add the flocculant. | |
| Quartz sand filter | Quartz sand, used to remove iron,colloid,silt etc, to make effluent water cleaning. | |
| Active carbon filter | Remove color, free chloride, organic matter, harmful matter, etc. | |
| Dosing system | Detail dosing system will be decided by: source quality & treated water quality requirements. Normal including: inhibitor dosing, PH dosing, reducing dosing, germicide dosing. |
|
| 2. RO sea water plug system | Security filter | Prevent large particles, iron, dust, SS matter, impurity into the RO membrane. |
| HP pump | Provide power for RO. CNP pumps ,Grundfos pumps,or other brands. | |
| RO membrane | Removes: lead, cooper, barium, chromium, mercury, sodium, cadmium, fluoride, nitrite, nitrate, and selenium. |
|
| 3. Control system | Control panel | Auto type. |
| Touch screen | Convenience for user to operate. | |
| Electricity components | Schneider/Omron/Siemens | |
| Plant skid | Ss304 or CS | |